Frequently asked questions by health care professionals


This page is provided in order to address many of the common concerns that doctors and dentists typicaly ask about Clifford Materials Reactivity testing policies and proceedures. If you have a qestion that is not adequately addressed here please contact us for further information.

Downloads Page

Main FAQ's
Pose a question online


Is this testing an exhaustive evaluation of immune response to biomaterials?
What is the basis for the Clifford Materials Reactivity Testing?
What is specificity?
Is testing reproducible?
Where can I get testing that has greater depth and quantifying capabilities than just a screening procedure such as the Clifford Materials Reactivity Testing?
Does the Clifford Materials Reactivity Testing actually test finished samples of restorative materials with blood or other specimens from the donor?
How is specificity shown?
Does the order in which the challenges are presented make any difference?
Can you stop the formation of precipitates altogether other than by adding challenges?
Can a combination of antigen and antibody be demonstrated by any other means except simple precipitation in a tube?
Have any other methods been used that suggest the reactions being observed are antigen and antibody based activities?
Why are these other methods not routinely used along with the precipitin method?
What equipment is used for the precipitin evaluation?
Can't the photometric scanner do better than a human eye?
Is there any kind of quality control program in this testing?
Why don't you routinely quantify with end-point titrations?
Can the testing prove that existing fillings are the cause of sensitization?
How do you know that you are actually detecting antibodies, and not just observing some general precipitation of serum proteins?
How do you know that globulin or other protein remains in the supernatant fluids after precipitates or reaction combinations are formed with challenge materials?
Does testing ever have false positive findings?
Does testing ever have false negative findings?
If false positives and false negatives can occur, why bother with testing at all?
Can metals really be considered an adequate antigen?
Do antibiotics or vitamin supplements adversely affect testing results?
Do these antibodies represent a direct measurement of how much offending substance was taken into the donor or which now resides in the donor's body?
Do these antibodies indicate how sensitive the donor is to the offending substance?
If a large quantity (high titer) of antibody is found, doesn't this mean the donor is highly sensitive?
Can antibody levels (titers) rise and fall, or change over time?
Does testing prove that existing fillings need to be removed?
How do you know that these bands are antigen and antibody combinations?
Can the amount of antibody present be quantified?
What patient symptoms prove correlation between sensitization and pathology?
Does sensitivity found in this testing correlate to hair testing results for presence of heavy metals?
Does this testing correlate with other avenues of evaluation such as electrodermal, kinesiologic and radionic methods?
When a patient is shown by Clifford Materials Reactivity Testing to have a sensitivity to aluminum salts, why are products containing aluminosilicates not routinely contraindicated?
Why do some insurance carriers not cover testing?
Why doesn't Clifford Consulting & Research participate with the US Medicare program?
Why don't you publish a complete listing of all dental products and their component parts and combined testing rankings?


Is this testing an exhaustive evaluation of immune response to biomaterials?

No. This testing is intended to be a screening procedure with the presence of antibody at or above a relevance level serving as an indicator of prior adverse exposure with sufficient intensity to induce sensitization. It does not pretend to evaluate immune functional capacity nor measure current threshold levels. It is intended to be a comparatively inexpensive means for obtaining guidance in selecting those restorative materials which can be used with least amount of risk for the patient.

back

What is the basis for the Clifford Materials Reactivity Testing?

The basis for testing is the detection of antibodies from donor serum which are produced when the immune system comes into contact with toxic, noxious or irritating substances. These antibodies will principally be from the systemic classes IgG, IgM and occasionally from IgA.

back

What is specificity?

Specificity in antibodies indicates that a certain antibody will react only with the specific irritant or toxic substance (antigen) which caused it to be formed. Specificity can occur in degrees, wherein some antibodies may react with a related group of substances which have some similarities in structure. Normally, specificity suggests a strict lock and key fit between the antibody and the antigen against which it was made, with exclusion of any combination with other substances.

back

Is testing reproducible?

Yes. If a single sample is split into multiple portions, handled identically and tested identically, the precision of testing is better than 97%. If a donor has blood drawn each day over a period of several days, qualitative test results will correlate at 95% or better if handling, processing, temperature, and storage are kept in close control.

back

Where can I get testing that has greater depth and quantifying capabilities than just a screening procedure such as the Clifford Materials Reactivity Testing?

Clifford Consulting & Research is in developmental stages of a provocative challenge testing system with both positive uptake and exclusion to deal with higher level detection and to help those who have problems which do not stimulate antibody production. As well, certain cytotoxic tests and lymphocyte culture methods may be available where additional help is needed. Laboratories and professionals providing this kind of service may include Dr. Russell Jaffe at the Physician's SerImmune Lab in Reston, Virginia.

back

Does the Clifford Materials Reactivity Testing actually test finished samples of restorative materials with blood or other specimens from the donor?

No, it does not. The finished, intact restorative product is seldom, if ever, toxic to patients. Rather, it is the corrosion by-products, the ionizable breakdown products and out-gassing or off-loadable components which cause materials related problems. The testing uses a list of 96 chemical groups and families of compounds for testing. These results are correlated with our database of dental and orthopedic products material composition and expected chemical breakdown over time.

back

How is specificity shown?

Specificity in this type of testing is demonstrated by showing that globulin in a donor specimen can react with a certain quantity of a single challenge such as mercury salts, aluminum salts, acrylate compounds, etc. After the resulting precipitate or formed combination is centrifuged out, the remaining globulin will not react further by adding more of this single challenge. The precipitate or product can be shown to contain principally the target challenge material and globulin. When a second single challenge is added to the serum specimen, however, a new quantity of precipitate or combination product is formed. If separated out, this second precipitate or combination contains principally the second single challenge substance and globulin. Adding more of the second challenge to the serum specimen produces no more reaction. The serum specimen can be shown to contain remaining globulin, meaning that the steps of adding two challenge materials and removing their reaction products did not simply remove all globulin and protein indiscriminately from the serum. If a third challenge is added, the same observations prevail as with the previous two challenges. This assumes that the donor has a sensitization to all three challenge materials. Even after removing the products of the third challenge, there will be remaining globulin in the test serum supernatant fluid. The challenges removed only that globulin (antibody) which was specifically produced against the challenge in question.

back

Does the order in which the challenges are presented make any difference?

No. We have demonstrated that sequence is inconsequential using aluminum, copper and mercury salts as the challenge materials. The only qualification is that the donor must be sensitized and have demonstrated antibody titers for each challenge

back

Can you stop the formation of precipitates altogether other than by adding challenges?

Yes. A simple technique of precipitating proteins generally and non-specifically from the serum by adding ammonium sulfate renders the specimen incapable of forming further precipitates with any of the challenge materials. Supernatant serum fluids treated in this manner will have virtually no albumin or globulin when analyzed by serum chemistry test methods.

back

Can a combination of antigen and antibody be demonstrated by any other means except simple precipitation in a tube?

Yes. When wells are prepared in an agar test plate such that serum can be placed in a central well and challenge solutions are placed individually in outer surrounding wells, the formation of precipitin bands between the serum and challenge wells are observed in 18-24 hours. If challenges are mixed together in a single well and allowed to diffuse out into the agar towards the serum test well, multiple precipitin bands are seen routinely. This general technique is referred to as an Ouchterlony double gel diffusion

back

Have any other methods been used that suggest the reactions being observed are antigen and antibody based activities?

Yes. In addition to general liquid precipitation and Ouchterlony double diffusion techniques, the latex agglutination technique and sheep red cell hemagglutination inhibition method have been successfully used for testing purposes.

back

Why are these other methods not routinely used along with the precipitin method?

Our studies have shown that each of the four mentioned methods give similar results. They have shown good cross-checking on each other. The precipitin method is by far the most simple and straight-forward to carry out. As a matter of logistics, timely reporting and cost to patient, we have found that the precipitin method is reliable, stable and well suited to a screening procedure.

back

What equipment is used for the precipitin evaluation?

The testing is completed in a microtiter environment. Reading is performed on a multiple wavelength photometric scanner. After the machine has used two wavelengths to determine density, the final evaluation of the plate is made by visual inspection by experienced personnel to help in differentiating between a true precipitin reaction and certain non-specific agglutinations which can sometimes occur simply by mixing chemicals with serum in the presence of air.

back

Can't the photometric scanner do better than a human eye?

Yes and No. The photometric scanner can evaluate density measurements with very fine gradations and precision which are not possible by visual inspection. We use the scanner to obtain fundamental density readings for all specimens. These readings are captured by computer and electronically processed to reduce the likelihood of human transcription and judgemental errors.However, simple density is not the only important evaluation which must be made. For example, it is also important to know that we are evaluating a precipitin reaction and not a simple non-specific agglutination of serum protein which can occur when certain chemicals are mixed with serum out in the air. Evaluation of granularity can easily be made by a trained eye. Sometimes, light can be refracted and diverge into a split spectrum which results in an opalescent appearance, especially near the boundaries of the specimen. This quality is also best observed by eye, and helps to insure that we are evaluating a true precipitin reaction. Thus, we will examine test specimens by trained eye after they are photometrically evaluated by a high-quality state-of-the-art scanner. The use of both machine and visual evaluation helps us insure a higher level of quality in the evaluation of patient specimens and helps substantially reduce the incidence of reporting false positive data which could result if the scanner is used by itself.

back

Is there any kind of quality control program in this testing?

Absolutely, yes. Quality control of the testing process is mandatory for laboratory licensure. Control sera have traditionally been drawn carefully from excess patient sera that are accumulated in the testing process. At Clifford Consulting & Research, we are working to transfer all control sera out of human source to commercially produced animal source. Positive and negative controls are routinely performed each testing day.

back

Why don't you routinely quantify with end-point titrations?

There is no useful reason to do so. Such measurement might be academically satisfying, but no additional clinical indications would result. The amount of antibody present will indicate something about currency and quality of exposure, but can change and will drop if no further challenge is presented. There is no valid correlation between amount of antibody present and degree of sensitivity in the donor. End-point titration could cause the price of testing to rise into the $1500-$2000 range, and the result would still suggest no more than sensitivity exists in the donor.

back

Can the testing prove that existing fillings are the cause of sensitization?

No, it cannot. Systemic sensitization can come from a variety of sources, including food, water, environment and lifestyle. Existing fillings may be involved or may contribute to sensitization, but the testing cannot demonstrate the specific relationship. The dentist or physician, with proper examination and clinical judgment, may determine that the fillings already in place are well-corroded and show signs of margin leakage, etc. On the basis of clinical judgment, together with test findings, the professional may suggest that replacement would be desirable. The testing, however, cannot serve as "proof" that existing dental restorations are the sole or primary factors in sensitization.

back

How do you know that you are actually detecting antibodies, and not just observing some general precipitation of serum proteins?

The testing has successfully demonstrated both specificity and reproducibility of results using multiple antibody detection methods. The precipitates and residues from the various methods contain both the target substance (antigen) and globulin (antibody protein). What happens if the donor is sensitive to only two of the three challenges?From our work, there will be no precipitate formed with the challenge for which there is no sensitivity.

back

How do you know that globulin or other protein remains in the supernatant fluids after precipitates or reaction combinations are formed with challenge materials?

Supernatant fluids have been shown to contain both albumin and globulin using simple serum chemistry test methods. The quantity of globulin reduces after each challenge is added and the precipitate is removed, but does not completely disappear. Albumin may vary slightly, but does not alter materially.

back

Does testing ever have false positive findings?

Yes. False positive findings are believed to occur generally when antibodies against one kind of challenge lack complete specificity and cross react with certain other challenges. These cross reactions in testing are not necessarily bad in that the same cross-reactivity may well occur in-vivo. Frequency rate for cross reactivity is believed to be less than 5% of findings. An example of antibodies which frequently cross react are those which act with cadmium and beryllium.

back

Does testing ever have false negative findings?

Yes. Most false negative findings are believed to occur when sensitization occurs, but residual antibody levels fall below test detection limits. A patient may have the capacity to react very strongly when new challenge is introduced, and antibody levels can rise very rapidly. If there is not sufficient antibody to detect, testing will miss the sensitivity. In certain patients, sometimes referred to as universal or environmental reactors, sensitivity may occur at a cellular contact level and never stimulate an immune defense. In these patients, there may not be any antibody production to detect, even though reactivity is a problem. Patients who have been on long-term immuno-suppressive treatments such as with corticosteroids may have abnormal suppression of antibody levels and may not be good candidates for this kind of testing. Based upon clinical feedback, the occurrence of false negatives is believed to be a very infrequent factor in patient treatment protocols. If false positives and false negatives can occur, why bother with testing at all? The value of testing is to screen and identify substances which should be avoided and to identify products which can be used with least degree of risk. Testing cannot remove all of the risk. Although infrequent, based upon clinical feedback and experimental longitudinal test series, there is always the potential for new, de novo sensitivities to occur. However, those products which do show as contraindicated have definite basis to be avoided, and the risk factors in treatment are materially reduced by identifying those products. As testing is further refined with time, the risk levels may be reduced even further.

back

Can metals really be considered an adequate antigen?

In most cases, metals will serve as a very valuable part of the antigen referred to as a hapten. There is good indication in published data that metals can fill such a role. Specificity studies at our own bench seem to confirm this. Some of the light metals such as sodium, potassium and magnesium are not suitable. It is likely that in the antibody stimulation process, most metals will be bound to proteins, ligands, saccharides and other carriers. They are quite capable of affecting the templating for antibody production.

back

Do antibiotics or vitamin supplements adversely affect testing results?

No, they do not. Long-term corticosteroid usage or other immuno-suppressive treatments may have an adverse affect by depressing antibody levels or altering their ability to function normally. We are not aware of any such interference by antibiotics, vitamin or mineral supplements, thyroid supplements, diuretics, etc. If a practitioner or patient determines that they will cease medications prescribed for patient use by competent health professionals, please be sure to inform the prescribing professional in advance of cessation and insure that the patient knows those which can be instantly stopped and those which must be reduced gradually. Even immunosuppressive substance cessation may require complete clearance for up to 90 days before immune competence is reasonably normal again. Some patients will not be able to make such cessations safely and should be properly warned and counseled against taking their own unilateral actions.

back

Do these antibodies represent a direct measurement of how much offending substance was taken into the donor or which now resides in the donor's body?

No, they do not. Antibodies are produced in response to a challenge to the immune system with an offensive substance (antigen). Depending on location within the body, binding site affinity, amount of absorption, bio-availability and elimination rate, the amount of antibody (titer) present is not necessarily proportional to either body burden or total exposure.

back

Do these antibodies indicate how sensitive the donor is to the offending substance?

No, they do not. They are used only as an indicator system of adverse exposure and resulting systemic sensitization. Sensitivity determination from antibody presence is a fundamental "yes / no" issue.

back

If a large quantity (high titer) of antibody is found, doesn't this mean the donor is highly sensitive?

No, it does not. High titers (or strongly reactive findings) of antibody may indicate a current or recent, high-quality exposure to the offending substance. If there is no continuing quality exposure, the quantity (titer) of antibody can fall even though there is an existing sensitivity programmed into cells such as the memory lymphocytes. A low titer (or weakly reactive finding) suggests either an extended period of time since last exposure to the offending material, a poor quality in the antigen (offending substance), or the possible onset of immune tolerance..

back

Can antibody levels (titers) rise and fall, or change over time?

Yes, they can. A continuing exposure to the offensive substance (antigen) may keep titers at higher levels, while absence of exposure may permit levels (titers) of antibodies to fall. The immune system may also establish a tolerance for the offending substance over time, in which the toxicity to body physiology does not change but the immune system’s ability or inclination to fight the substance drops.

back

Does testing prove that existing fillings need to be removed?

No, for the same reasons cited above. Only clinical judgement can place test findings in the proper light and evaluate replacement needs.

back

How do you know that these bands are antigen and antibody combinations?

We have excised the bands from agar plates after 24 hours for testing. Each band contains principally its target challenge and globulin. There is relatively good isolation between the bands and concentrations of target challenge substance will average two orders of magnitude greater concentration than for other challenges included in the mixtures if challenges were mixed prior to diffusion.

back

Can the amount of antibody present be quantified?

Yes. In our studies, we have experimentally performed endpoint titrations, which are an acceptable means of quantifying antibody when a known concentration of challenge is used. A typical result might indicate that a certain challenge titers out to 1:256.

back

What patient symptoms prove correlation between sensitization and pathology?

There are few set correlations of symptoms and toxicity in medicine. When tainted food containing certain endo and exotoxins from Clostridium perfringens or from Staphylococcus aureus is ingested, patients may have nausea, vomiting, headache, stomach cramps, diarrhea, esophageal reflux, gas, joint pains, light-headedness, insomnia, tachycardia, tetany, fever, edema, depression and sweats to name a few of the symptoms. Not every patient will have every symptom, and intensity of reaction will usually vary throughout the affected population. Some individuals will have little or no difficulty at all. Toxic responses as well as the formation of antigen-antibody complexes in-vivo seldom have identical epidemiological presentations in the population and are clearly threshold based. Toxicity and the formation of immune complexes in-vivo from restoratives breakdown fall into the same gamut of considerations.

back

Does sensitivity found in this testing correlate to hair testing results for presence of heavy metals?

Sometimes, but not always. Presence of heavy metals does not necessarily prove toxicity or physiological interference. Alternative pathways, genetic predispositions and individual threshold levels may permit a relatively high body burden of certain toxic substances to accumulate without any outward sign of impairment. Body burden alone should not be taken as an absolute indication of poisoning. Obviously, reduction of known toxic substances in the body burden cannot be taken as useless even in the absence of symptoms.

back

Does this testing correlate with other avenues of evaluation such as electrodermal, kinesiologic and radionic methods?

Frequently, yes. There may occasionally be some subtle differences. When evaluations of any kind are performed using samples of finished dental products as the reference point, there may be differences between such finished products and the breakdown or corrosion byproduct forms of these products. When multiple avenues of evaluation are available, if any one method indicates a problem with a certain product, it probably should be removed from further consideration even if other methodologies do not pick up on the same contraindication. Each method offers certain strengths and certain weaknesses.

back

When a patient is shown by Clifford Materials Reactivity Testing to have a sensitivity to aluminum salts, why are products containing aluminosilicates not routinely contraindicated?

It is not the absolute content of the restorative product, but rather the ionizability or dissociability of things like aluminum to exit the restorative that make a difference. The half-life of an aluminosilicate (a measure of its ability to break down and give off half of its individual components) is conservatively in the hundreds of thousands of years for conditions of the oral cavity, and in practice is probably much longer. For this reason, even the most severely aluminum-sensitive patients can safely use a drinking glass from the kitchen or have contact with sand on the seashore (both aluminosilicates). To be toxic, the aluminum must be ionized and offloaded from the restorative and then bound to available carriers. Some dental products will use various forms of aluminum compounds for purposes of radiopaqueness, luster and lucency, pigmenting and texturing. These aluminum addition forms can often dissociate, and are of much greater concern. Contraindication of a product due to content of things like aluminum is based upon dissociability rather than absolute content.

back

Why do some insurance carriers not cover testing?

Our testing is intended for dental application and is clearly outside of the policy provisions which are held by some patients. Some carriers do not pay unless the majority of health practitioners within a given area use the testing. We know that some carriers do reimburse their policy holders according to policy provisions when proper procedural codes and diagnosis codes are supplied. Clifford Consulting & Research has current industry standard procedural codes (CPT codes) and provides them on every receipt which we send out with test copies. Only a physician or dentist can render a diagnosis of patient conditions. In a substantial number of insurance denials, a diagnosis code (ICD-9 code) from the doctor is either lacking or not properly supported. On a more positive note, an increasing number of insurance carriers are participating within the conditions of their policies for testing. A current ICD-9 codebook can be obtained from the publications and book resale division of the American Medical Association.

back

Why doesn't Clifford Consulting & Research participate with the US Medicare program?

Clifford Consulting & Research has declined to participate with Medicare for several reasons. These include (1) the practice of Medicare to automatically and routinely discount their payments for laboratory services, (2) the regular denial of claims for routine dental-related services, (3) the exceptional burden of paperwork and delay in receiving payment for work provided to Medicare patients and (4) the inability to reasonably challenge a denial if Medicare decides the testing was not needed. There would be a need to artificially inflate laboratory charges for non-Medicare patients in order to cover the shortfall induced by Medicare patients. As a non-acute care facility, our routine response (as suggested to us by Medicare personnel) when asked to provide services for Medicare patients is to regretfully decline to do so, or to provide the opportunity for the patient to privately contract with the lab for service. Under this private arrangement, the services provided are not eligible for Medicare submission and payment and must be paid in full by the patient. Patients are provided with an advance notification of this arrangement and asked to acknowledge their understanding of Medicare non-participation on the testing order form with signature when a specimen is submitted to the laboratory. Those wishing not to enter such an arrangement are referred back to their doctor for assistance with other testing or testing sources..

back

Why don't you publish a complete listing of all dental products and their component parts and combined testing rankings?

For several reasons: Some companies who make restorative products have been very forthright in sharing proprietary data with Clifford Consulting & Research on condition that we respect and protect the confidence. Companies are not required to completely reveal everything about their products under current government regulation, and may alter their formularies from time to time without notifying anyone. Clifford Consulting & Research does not wish to take responsibility for becoming a public clearinghouse for product information, nor does it have the right to do so. This is especially true when companies become hostile and hide their changes. Some companies who make products which are frequently contraindicated by testing are more inclined to bring legal actions when public exposure of their products are made. We can defend our test findings, but have no desire to spend twenty to thirty thousand dollars or more for the privilege every time someone decides to take up a crusade to protect a product line. When someone wants to know what is contained in "product X", we simply suggest they contact the manufacturer's public relations department and inquire. This permits the company the option to say whatever they chose about their own products.

back

 


 
 